Best UP27I SERIES Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Hottes de cuisine Best UP27I SERIES. Best UP27I SERIES Installation manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
UP27I and UP27E SERIES
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE AND OPERATION INFORMATION ON
PAGES 13 AND 14.
V07855 rev. A
HB0061
INSTALLATION INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
!
!
In USA - BEST BY BROAN
®
P.O. Box 140, Hartford, WI 53027
In Canada - BEST BY BROAN
®
550 Lemire Blvd., Drummondville, QC, J2C 7W9
REGISTER YOUR PRODUCT ON LINE AT: www.bestbybroan.com/register
For additional information - visit www.bestbybroan.com
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - UP27I and UP27E SERIES

UP27I and UP27E SERIESINTENDED FOR DOMESTIC COOKING ONLYINSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.HOMEOWNER: USE AND CARE AND OPERATION INFORMATION

Page 2 - WARNING WARNING

- 10 -8. PREPARE THE HOOD (CONT’D)8.1 UP27I SERIES RANGE HOOD (INTERNAL BLOWER) (CONT’D)HORIZONTAL DISCHARGE (DUCTED INSTALLATION ONLY)(CONT’D)Using 3

Page 3 - INTERIOR BLOWER

- 11 -10.INSTALL THE HOODPlace the hood at its location. Using a pen, mark the position of the screw (smaller part of the keyholes [A]). Remove the ho

Page 4 - IN-LINE AND EXTERIOR BLOWERS

Reinstall the grease drip rail.13.REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERS13.1 DUCTED INSTALLATION:Reinstall Evolutionary™ hybrid baffle filters

Page 5 - 1.3 ALL INSTALLATIONS

- 13 -15.USE AND CAREEvolutionary™ Hybrid Baffle FiltersThe Evolutionary™ hybrid baffle filters should be cleaned frequently. Use a warm detergent sol

Page 6 - 3. REMOVE THE FILTERS

- 14 -16.OPERATION (CONT’D)HEAT SENTRYBoth UP27I and UP27E series are equipped with a HEAT SENTRY thermostat. • If blower is ON at a lower speed setti

Page 7 - 6. REMOVE THE PAN

- 15 -SERVICE PARTSKEY PART QTY (HOOD WIDTH)NO. NUMBER DESCRIPTION 30’’ 36’’ 42’’ 481 V14971 ADAPTER/DAMPER 3¼” X 14” 1 1 1 12 T461 ADAPTER/DAMPER 3¼”

Page 8 - 8. PREPARE THE HOOD

- 16 -SERVICE PARTSKEY PART QTY (HOOD WIDTH)NO. NUMBER DESCRIPTION 30’’ 36’’ 42’’ 48’’1 V13923 FEMALE CONNECTOR 11112 V13924 MALE CONNECTOR 11113 V034

Page 9

WARNING WARNING- 2 -TO REDUCE THE RISK OF FIRE, ELECTRICSHOCK OR INJURY TO PERSONS, OBSERVETHE FOLLOWING:1. Use this unit only in the manner intended

Page 10 - 9. CONNECT WIRING

HL0086- 3 -Model 415(7” roundadjustableelbow,optional)Model 4188” roundadjustableelbow,(optional)UP27I SERIESHOOD(Canopy with internalblower, controls

Page 11 - 12.REINSTALL THE PAN

- 4 -HL0087- UP27E SERIES RANGE HOOD SYSTEM -IN-LINE AND EXTERIOR BLOWERSIn-line and exterior blower rough-in kit(included with EB6, EB9, EB12, EB15,I

Page 12 - 14.LIGHT BULBS REPLACEMENT

- 5 -1. SELECT BLOWER OPTION AND INSTALLATION TYPE1.2 DUCTED INSTALLATIONEither UP27I or UP27E Series range hoods may be ducted. For a UP27E Series ra

Page 13 - 16.OPERATION

Remove the installation kit from inside the hood.Make sure that the following items are included:- Installation manual- Adapter/damper 3¼” x 14” to

Page 14 - 16.OPERATION (CONT’D)

- 7 -7. PREPARE THE CABINETFor cabinets with recessed bottom, attach two wood filler strips cut to length (not included), on each side, as shown below

Page 15 - SERVICE PARTS

- 8 -7. PREPARE THE CABINET (CONT’D)7.1 DUCTED INSTALLATION:Cut-out the openings for duct (A) and house wiring (120 V AC)(B) according to the directio

Page 16

- 9 -HORIZONTAL DISCHARGE (DUCTED INSTALLATION ONLY)The UP27I Series range hoods are factory set to exhaust vertically. If the horizontal discharge is